Always “On” UPS Systems Inc.
GES L-Series – Single Phase Input, Single Phase Output
Uninterruptible Power Supply
USER MANUAL
Version 1.4
GES-801L, GES-102L, GES-152L, GES-202L, GES-302L
Line Interactive (True Sine Wave):
800VA, 1000VA, 1500VA, 2000VA, 3000VA
Extended Run-Time Battery Banks
Available on All Models
Zobrazit stránku 0
1 2 3 4 5 6 ... 21 22

Shrnutí obsahu

Strany 1 - Uninterruptible Power Supply

Always “On” UPS Systems Inc. GES L-Series – Single Phase Input, Single Phase Output Uninterruptible Power Supply USER MANUAL Version 1.4 GES-801L, GES

Strany 2

Always “On” UPS Systems Inc. 10 Installation Unpacking and Inspection Examine the packaging for damage. Inform the carrier immediately if and/or when

Strany 3

Always “On” UPS Systems Inc. 11 Connecting the Telephone/Modem/Ethernet Lines Connect a telephone line, modem line, or 10BaseT line into the telephone

Strany 4

Always “On” UPS Systems Inc. 12 Operation Switching “On” the UPS With the UPS plugged in, press and hold the “ON/TEST” button for at least 1 second t

Strany 5

Always “On” UPS Systems Inc. 13 Battery Charge Bar Graph This 5 LED display indicates the present charge of the UPS's batteries as a percentage o

Strany 6

Always “On” UPS Systems Inc. 14 Software Options UPSilon 2000 Software The UPSilon 2000 software utilizes standard RS-232 interface to perform monito

Strany 7

Always “On” UPS Systems Inc. 15 Computer Interface Port The computer interface port has the following characteristics: The communication port on the

Strany 8

Always “On” UPS Systems Inc. 16 Battery Replacement Your batteries should run anywhere from 3-5 years before they need to be replaced. Please follow

Strany 9

Always “On” UPS Systems Inc. 17 Troubleshooting Please follow the guidelines below for solutions to common problems:  Check UPS input plug and wiri

Strany 10 - Always “On” UPS Systems Inc

Always “On” UPS Systems Inc. 18 Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged.

Strany 11

Always “On” UPS Systems Inc. 19 Battery Bank Installation Install up to 8 battery banks per L Series UPS following the instructions below. Cau

Strany 12

Always “On” UPS Systems Inc.

Strany 13

Always “On” UPS Systems Inc. 20 Specifications Specification Comparison MODEL NO. GES-801L GES-102L GES-152L GES-202L GES-302L MAXIMUM CAPACITY 80

Strany 14

Always “On” UPS Systems Inc. 21 OUTPUT SHORT YES ABNORMAL VOLTAGE YES MODEM OR NETWORK SINGLE LINE (2 wire RJ11) / NETWORK (UTP, RJ45) COMPATIBLE J

Strany 15

Always “On” UPS Systems Inc. 22 CONTACT INFORMATION Additional Purchases or Upgrades Always “On” UPS Systems Inc. Bldg 1 – 150 Campion Road, Kelow

Strany 16

Always “On” UPS Systems Inc. 3 SAVE THESE INSTRUCTIONS  This manual contains important instructions for the GES-801L, GES-102L, GES-152L, GES-202L,

Strany 17

Always “On” UPS Systems Inc. 4 TABLE OF CONTENTS INTRODUCTION...

Strany 18

Always “On” UPS Systems Inc. 5 Introduction The L-Series is a Line Interactive UPS system that includes the newest and latest technology enhancements

Strany 19 - 4

Always “On” UPS Systems Inc. 6 Safety Instructions The UPS has its own internal energy source (batteries), therefore the output receptacles may have

Strany 20

Always “On” UPS Systems Inc. 7 Presentation Front Panel 1. POWER bar graph (BATTERY CHARGE/LINE VOLTAGE) This displays the present battery charge as

Strany 21

Always “On” UPS Systems Inc. 8 Rear Panel 11. TELEPHONE/MODEM/ETHERNET SURGE PROTECTION Surge protection for telephone line, modem line, and 10Base

Strany 22

Always “On” UPS Systems Inc. 9 16. INPUT CIRCUIT BREAKER It trips when the connected loads exceed the protected receptacle's capacity. The center