MGE UPS Systems 5000 RT Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Nepřerušitelné zdroje napájení (UPS) MGE UPS Systems 5000 RT. MGE UPS Systems 5000 RT User manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Pulsar MX

Pulsar MX5000 RT — UPSEXB RT — Extended BatteryTransformer 5000Installation and User Manualwww.mgeops.com

Strany 2

(This page left blank intentionally)Pulsar MX486-87050-00 A01

Strany 3

Presentation1.1 Standard PositionsTower PositionRack Position1 — 186-87050-00 A01 PresentationDimensions (H x W x D) in inches/mmPulsar MX 5000 RT17.

Strany 4

1.2 Rear PanelsPulsar MX 5000 RT Pulsar MX EXB RT Transformer 5000(1) One group of 4 L6-30R outlets for connection of equipment(2) Output terminal bl

Strany 5 - Contents

1.3 Display and Control Panel1.4 Accessories for Rack MountRack Mounting KitTelescopic rails for Pulsar MX RT mounting in 19’’ enclosure with mounting

Strany 6 - Who to Contact

1.5 Extended Battery (EXB)Pulsar MX RT offers a standard backup time of 5 minutes at full load. To increase backup time, it is possible to connectPuls

Strany 7 - Introduction

2 — 186-87050-00 A01 Installation2.1 Unpacking and Contents CheckUPS Module Contents (87050)Optional Transformer Module Contents (87102)Step down tran

Strany 8 - IMPORTANT SAFETY INSTRUCTIONS

2.2 Internal Battery Connection (Battery Start-up)2.3 Installation in Tower PositionFollow steps 1 to 3 in the illustration below to adjust the tower

Strany 9 - Symbol Usage

2.4 Installation in Rack PositionAdjustment of the orientation of the logo and control panelUPS module rack mountingPulsar MX RT is very heavy. To eas

Strany 10

Do not install the UPS or battery module in hermetic closed environments without any exchange of air.Follow steps 1 to 4 for rack mounting the UPS ont

Strany 11 - 1.1 Standard Positions

2.5 Communication PortsPulsar MX RT provides 4 communication methods.1. The RS232 port provides communications using MGE Office Protection Systems Ser

Strany 13 - 1.3 Display and Control Panel

Remote Power Off communication port (9)Installation of a Remote Power Off function must be carried out in compliance with applicable regulations.In or

Strany 14 - 1.5 Extended Battery (EXB)

2.7 Hardwire Connection of Output Power Cable to UPS◗ This type of connection must be carried out by qualified electrical personnel.◗ Before carrying

Strany 15 - UPS Module Contents (87050)

2.8 Connection to Output Receptacles2.9 Connection of Extended Battery Module, UPS, and Transformer1. Check that the battery circuit breaker(s) (13) i

Strany 16

Operation3.1 Initial Start-UpTo ensure that your system is configured in complete accordance with safety regulations and to benefit from the manufactu

Strany 17 - Installation and User Manual

Pulsar MX 3 — 286-87050-00 A01 3.3 Operating ModesNormal modeECO modeAC out of toleranceIf normal AC source is out of tolerance:LEDs (20), (21) are ON

Strany 18

3.4 Operation on Battery PowerWhen the Normal AC source is not available, the load continues to be protected by the UPS.Power is supplied by the batte

Strany 19 - 2.5 Communication Ports

3.5 Return to Normal AC SourceAfter an outage, the UPS restarts automatically when Normal AC source is restored (unless this function has been disable

Strany 20

Access to Maintenance and Personalization Data4.1 Display Organization4.2 Access to MeasurementsPress the scroll button (25) to access measurements fo

Strany 21 - 2 & 3

4.4 UPS Set-UpLocal SettingsOutput SettingsON/OFF SettingsFunction Factory Setting Options CommentsCold Start Disabled EnabledStart on batteryForced R

Strany 22

Battery Settings4.5 Maintenance4.6 UPS Set-Up Using External Software◗ Insert the Solution-Pac CD-ROM in the drive.◗ On the first navigation screen, s

Strany 23 - 3.2 Final Start-Up Sequence

Installation and User Manual86-87050-00 A01Pulsar MXInstallation and User ManualRevision HistoryPulsar MX Installation and User Manual, 86-87050-00 R

Strany 24 - 3.3 Operating Modes

(This page left blank intentionally)Pulsar MX 4 — 486-87050-00 A01

Strany 25

5 — 186-87050-00 A01 Troubleshooting5.1 Troubleshooting LEDS (21) and (22)5.2 Troubleshooting Not Requiring MGE Office Protection Systems After-Sales

Strany 26 - ON AUTO BYPASS

5.3 Troubleshooting Requiring MGE Office Protection Systems After-Sales SupportNote: In case of multiple fault, press the "Enter" button (27

Strany 27 - 4.2 Access to Measurements

Life Cycle Monitoring (LCM)6.1 DescriptionThis function, embedded in the UPS, displays messages on screen, and communication channels, at everyimporta

Strany 28 - 4.4 UPS Set-Up

(This page left blank intentionally)Pulsar MX Life Cycle Monitoring (LCM)6 — 286-87050-00 A01

Strany 29 - 4.5 Maintenance

Maintenance7.1 Hot Swapping the Power Sub-ModuleThis operation must be carried out by qualified electrical personnel only.This operation can be perfor

Strany 30

Pulsar MX86-87050-00 A01

Strany 31 - ENVIRONMENT FAULT

Appendix8.1 Technical specifications(1) If the output voltage is 200V — 250V, the output power is 5000VA / 4500W.(2) With one EXB module or more, the

Strany 32

Pulsar MX86-87050-00 A01

Strany 33 - 6.1 Description

86-87050-00 A01 MGE Office Protection Systems Customer Care CenterTechnical Support and Product ServicesTechnical questions? If you encounter a proble

Strany 34

Pulsar MX86-87050-00 A01

Strany 35 - Maintenance

Pulsar MX86-87050-00 A01

Strany 36

GlossaryBackup time Time that the connected equipment can operate on battery power.Bypass AC source Source supplying the bypass line. The equipment ca

Strany 37 - 8.1 Technical specifications

Notes:Pulsar MX86-87050-00 A01

Strany 39 - Customer Care Center

13 Whatney, Suite #101, Irvine, California 92618 • www.mgeops.comwww.mgeops.comContact MGE OfficeProtection SystemsUnited StatesMGE Office Protection

Strany 40

ContentsContentsc i86-87050-00 A01 Introduction ...

Strany 41 - Glossary

Pulsar MXContentsc ii86-87050-00 A01 Life Cycle Monitoring (LCM)6.1 Description ...

Strany 42

IntroductionThank you for selecting an MGE Office Protection Systems product to protect your electrical equipment.The Pulsar MX range has been designe

Strany 43

Pulsar MX286-87050-00 A01 IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed du

Strany 44 - Protection Systems

Symbol UsageImportant instructions that must always be followed.Information, advice, help.Visual indication.Action.Audible signal.LED offLED onInstall

Komentáře k této Příručce

Žádné komentáře