Pulsar MX5000 RT — UPSEXB RT — Extended BatteryTransformer 5000Installation and User Manualwww.mgeops.com
(This page left blank intentionally)Pulsar MX486-87050-00 A01
Presentation1.1 Standard PositionsTower PositionRack Position1 — 186-87050-00 A01 PresentationDimensions (H x W x D) in inches/mmPulsar MX 5000 RT17.
1.2 Rear PanelsPulsar MX 5000 RT Pulsar MX EXB RT Transformer 5000(1) One group of 4 L6-30R outlets for connection of equipment(2) Output terminal bl
1.3 Display and Control Panel1.4 Accessories for Rack MountRack Mounting KitTelescopic rails for Pulsar MX RT mounting in 19’’ enclosure with mounting
1.5 Extended Battery (EXB)Pulsar MX RT offers a standard backup time of 5 minutes at full load. To increase backup time, it is possible to connectPuls
2 — 186-87050-00 A01 Installation2.1 Unpacking and Contents CheckUPS Module Contents (87050)Optional Transformer Module Contents (87102)Step down tran
2.2 Internal Battery Connection (Battery Start-up)2.3 Installation in Tower PositionFollow steps 1 to 3 in the illustration below to adjust the tower
2.4 Installation in Rack PositionAdjustment of the orientation of the logo and control panelUPS module rack mountingPulsar MX RT is very heavy. To eas
Do not install the UPS or battery module in hermetic closed environments without any exchange of air.Follow steps 1 to 4 for rack mounting the UPS ont
2.5 Communication PortsPulsar MX RT provides 4 communication methods.1. The RS232 port provides communications using MGE Office Protection Systems Ser
Remote Power Off communication port (9)Installation of a Remote Power Off function must be carried out in compliance with applicable regulations.In or
2.7 Hardwire Connection of Output Power Cable to UPS◗ This type of connection must be carried out by qualified electrical personnel.◗ Before carrying
2.8 Connection to Output Receptacles2.9 Connection of Extended Battery Module, UPS, and Transformer1. Check that the battery circuit breaker(s) (13) i
Operation3.1 Initial Start-UpTo ensure that your system is configured in complete accordance with safety regulations and to benefit from the manufactu
Pulsar MX 3 — 286-87050-00 A01 3.3 Operating ModesNormal modeECO modeAC out of toleranceIf normal AC source is out of tolerance:LEDs (20), (21) are ON
3.4 Operation on Battery PowerWhen the Normal AC source is not available, the load continues to be protected by the UPS.Power is supplied by the batte
3.5 Return to Normal AC SourceAfter an outage, the UPS restarts automatically when Normal AC source is restored (unless this function has been disable
Access to Maintenance and Personalization Data4.1 Display Organization4.2 Access to MeasurementsPress the scroll button (25) to access measurements fo
4.4 UPS Set-UpLocal SettingsOutput SettingsON/OFF SettingsFunction Factory Setting Options CommentsCold Start Disabled EnabledStart on batteryForced R
Battery Settings4.5 Maintenance4.6 UPS Set-Up Using External Software◗ Insert the Solution-Pac CD-ROM in the drive.◗ On the first navigation screen, s
Installation and User Manual86-87050-00 A01Pulsar MXInstallation and User ManualRevision HistoryPulsar MX Installation and User Manual, 86-87050-00 R
(This page left blank intentionally)Pulsar MX 4 — 486-87050-00 A01
5 — 186-87050-00 A01 Troubleshooting5.1 Troubleshooting LEDS (21) and (22)5.2 Troubleshooting Not Requiring MGE Office Protection Systems After-Sales
5.3 Troubleshooting Requiring MGE Office Protection Systems After-Sales SupportNote: In case of multiple fault, press the "Enter" button (27
Life Cycle Monitoring (LCM)6.1 DescriptionThis function, embedded in the UPS, displays messages on screen, and communication channels, at everyimporta
(This page left blank intentionally)Pulsar MX Life Cycle Monitoring (LCM)6 — 286-87050-00 A01
Maintenance7.1 Hot Swapping the Power Sub-ModuleThis operation must be carried out by qualified electrical personnel only.This operation can be perfor
Pulsar MX86-87050-00 A01
Appendix8.1 Technical specifications(1) If the output voltage is 200V — 250V, the output power is 5000VA / 4500W.(2) With one EXB module or more, the
Pulsar MX86-87050-00 A01
86-87050-00 A01 MGE Office Protection Systems Customer Care CenterTechnical Support and Product ServicesTechnical questions? If you encounter a proble
Pulsar MX86-87050-00 A01
Pulsar MX86-87050-00 A01
GlossaryBackup time Time that the connected equipment can operate on battery power.Bypass AC source Source supplying the bypass line. The equipment ca
Notes:Pulsar MX86-87050-00 A01
13 Whatney, Suite #101, Irvine, California 92618 • www.mgeops.comwww.mgeops.comContact MGE OfficeProtection SystemsUnited StatesMGE Office Protection
ContentsContentsc i86-87050-00 A01 Introduction ...
Pulsar MXContentsc ii86-87050-00 A01 Life Cycle Monitoring (LCM)6.1 Description ...
IntroductionThank you for selecting an MGE Office Protection Systems product to protect your electrical equipment.The Pulsar MX range has been designe
Pulsar MX286-87050-00 A01 IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS. This manual contains important instructions that should be followed du
Symbol UsageImportant instructions that must always be followed.Information, advice, help.Visual indication.Action.Audible signal.LED offLED onInstall