34003641FR/AA - Page 1THEUNINTERRUPTIBLEPOWERPROVIDERwww.mgeups.comInstallation and user manualEvolutionS 1250 RT 2US 1750 RT 2U 2000 RT 2US 2500 RT
34008236EN/AA - Page 102. Installation2.4 Communication portsConnection of RS232 or USB communication port (optional) Installation of the communicati
34008236EN/AA - Page 112. Installation2.5 Connection with a FlexPDU (Power Distribution Unit) module (optional) 2.6 Connection with a HotSwap MBP mod
34008236EN/AA - Page 122. InstallationHotSwap MBP module operation UPS start-up with the HotSwap MBP module1 - Check that the UPS is correctly connec
34008236EN/AA - Page 133. Operation3.1 Start-up and normal operation 3.2 Operation on battery powerTransfer to battery power Low-battery warning Pr
34008236EN/AA - Page 143. OperationEnd of battery backup time 3.3 Return of AC input powerFollowing an outage, the UPS restarts automatically when AC
34008236EN/AA - Page 153. Operation Contact open: UPS shutdownContact closed: UPS start-up (UPS connected to AC power and AC power is available)
34008236EN/AA - Page 164. Personalisation using external software Main-output personalisation Voltage-threshold personalisation (1) Low threshold for
34008236EN/AA - Page 175. Maintenance5.1 Troubleshooting Troubleshooting a UPS equipped with the HotSwap MBP module Indication Diagnostic Correcti
34008236EN/AA - Page 185. Maintenance5.2 Battery-module replacementSafety recommendations The battery can cause electrocution and high short-circuit c
34008236EN/AA - Page 195. MaintenanceMounting the new battery moduleCarry out the above instructions in reverse order. 5.3 Maintenance on a UPS equip
34008236EN/AA - Page 2
34008236EN/AA - Page 206. Appendices6.1 Technical specifications (1) The high and low thresholds can be adjusted using Personal Solution-Pac softwa
34008236EN/AA - Page 216. Appendices6.2 Glossary Backup time Time during which the load can be supplied by the UPS operating on battery power.Battery
e-mail: [email protected]tel: 08-52 400 700 fax: 08-520 18121
34008236EN/AA - Page 3IntroductionEnvironmental protectionMGE UPS SYSTEMS has implemented an environmental-protection policy.Products are developed ac
34008236EN/AA - Page 4IntroductionPictograms Important instructions that must always be followed.Information, advice, help.Visual indication.Action
34008236EN/AA - Page 5Contents1. Presentation1.1 Standard positions ...
34008236EN/AA - Page 61. Presentation1.1 Standard positionsTower position Rack position Dimensions (W x H x D) in mmS 1250 RT 2US 1750 RT 2U2000 R
34008236EN/AA - Page 71. Presentation1.2 Rear panelsEvolution S 2500 / S 3000 Evolution S EXB (optional battery module) 1.3 Control panel (1) USB
34008236EN/AA - Page 82. Installation2.1 Unpacking and contents check (30) Evolution UPS(31) connection cable to AC-power source (Evolution S 2
34008236EN/AA - Page 92. Installation2.2 Installation in tower position 2.3 Installation in rack positionIt is advised to first install the battery m