51033212EN/AC - Page 1Comet EXtreme4.5/6/9/12 kVAComet EXtreme4,5/6/9/12 kVAInstallationand user manualComet EXtreme4.5/6/9/12 kVAwww.mgeups.comMGE U
Page 10 - 51033212EN/AC1. PresentationCLA module (Long backup time charger) for backup times of 2 to 8 hoursVery long backup times, from 2 to 8 hours
51033212EN/AC - Page 11bypass1. Presentation1.4 Control panel AlarmsUPS overloadElectronics faultBattery faultAmbient temp.> 40°CHold down to
Page 12 - 51033212EN/AC2. Installation2.1 Unpacking and checksElectronic moduleComet EXtreme 4.5 and 6 kVA23 24 2522battery module2527 RS 232 com
51033212EN/AC - Page 132. InstallationComet EXtreme 9 and 12 kVAElectronic module23242522Battery module2527 RS 232 communications cable. CD
Page 14 - 51033212EN/AC2.2 Installation of the rack version2. InstallationRack mounting diagram with railsThe rails and the necessary mounting hardwar
51033212EN/AC - Page 152. Installation2.3 Battery-module connectionsCheck that the battery circuit breaker is OFF.Check that the battery circ
Page 16 - 51033212EN/AC2. Installation2.4 Connection to the RS 232 communications port (optional)2.5 Installation of the communications-card optionSlo
51033212EN/AC - Page 172. InstallationThis type of connection must be carried out by qualified electrical personnel.Before carrying out any connectio
Page 18 - 51033212EN/ACbypassbypass3. Operation3.1 ON-LINE operating modeThis is the normal operating mode for the UPS.Two possible cases:LED is
51033212EN/AC - Page 19bypass3. Operation1114Prior to initial start-up, check the UPS voltage settings.The frequency of the output voltage (50 or 60
Page 2 - 51033212EN/ACIntroductionThank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.The Comet EXtreme range has
Page 20 - 51033212EN/ACbypassbypassbypass3. Operation3.4 Failure of AC input power and operation on battery powerAC input power is not available, the
51033212EN/AC - Page 213. Operation3.5 PersonalizationFunctionPersonalization parameters can be set and modified using the "UPS Driver" sof
Page 22 - 51033212EN/AC3. Operation"Battery" tabRated AC-power source voltage (see figure 1)Rated AC-power source frequencyTolerance for AC-
51033212EN/AC - Page 233. Operation221212Shutdown of connected equipment1. Press button (return to the OFF position).The connected equipment is
Page 24 - 51033212EN/AC4. Maintenance4.1 TroubleshootingIf one or more LEDs , , or flash, there is a operating anomaly or an ala
51033212EN/AC - Page 254. MaintenanceTroubleshooting requiring MGE after-sales supportIndicationLED flashes and the buzzerbeeps.LED flash
Page 26 - 51033212EN/ACbypass4. Maintenance4.2 Replacement of the electronic module1. Turn the manual bypass switch , located behind the UPS(see
51033212EN/AC - Page 271. Secure the connection module using the two screws .2. Reconnect the connection cable(s) to the battery module(s)
Page 28 - 51033212EN/AC5. EnvironmentThis product has been designed to respect the environment:It does not contain CFCs or HCFCs.It was manufactured i
51033212EN/AC - Page 296. Appendices6.1 GlossaryAuthorized voltage Upper and lower voltage thresholds within which the UPS can operaterange for trans
51033212EN/AC - Page 3ForewordUsing this documentInformation may be found primarily by consulting:◗ the contents,◗ the index.PictogramsImportant inst
Page 30 - 51033212EN/AC6. AppendicesOut of tolerance The AC input source is either absent or its voltage or frequency is outside theset limits.Percent
51033212EN/AC - Page 316. Appendices6.2 IndexAAC powerFailure ... 20Frequency tolerance ...
Page 32 - 51033212EN/AC
Page 4 - 51033212EN/ACContents1. Presentation1.1 Comet EXtreme range ...
51033212EN/AC - Page 5Contents3.4 Failure of AC input power and operation on battery power... 20Tran
Page 6 - 51033212EN/AC1. Presentation1.1 Comet EXtreme range4.5 and 6 kVA tower models4.5 and 6 kVA rack modelsElectronic moduleBattery moduleDimensio
51033212EN/AC - Page 71. Presentation9 and 12 kVA tower models9 and 12 kVA rack modelsElectronic moduleBattery moduleDimensions in mm(H x W x D)443 x
Page 8 - 51033212EN/AC1. Presentation1.2 BackRS232 communications port.Battery circuit breaker.Communications-card option.EXB battery module connector
51033212EN/AC - Page 91. Presentation1.3 OptionsTransformer for galvanic isolation or earthing arrangement changeImportant: to simplify installation,