51033212EN/AC - Page 1
Comet EXtreme
4.5/6/9/12 kVA
Comet EXtreme
4,5/6/9/12 kVA
Installation
and user manual
Comet EXtreme
4.5/6/9/12 kVA
www.mgeups.com
MGE UPS SYSTEMS
T
H
E
U
N
I
N
T
E
R
R
U
P
T
I
B
L
E
P
O
W
E
R
P
R
O
V
I
D
E
R
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - Comet EXtreme

51033212EN/AC - Page 1Comet EXtreme4.5/6/9/12 kVAComet EXtreme4,5/6/9/12 kVAInstallationand user manualComet EXtreme4.5/6/9/12 kVAwww.mgeups.comMGE U

Strany 2 - Introduction

Page 10 - 51033212EN/AC1. PresentationCLA module (Long backup time charger) for backup times of 2 to 8 hoursVery long backup times, from 2 to 8 hours

Strany 3 - ◗ the index

51033212EN/AC - Page 11bypass1. Presentation1.4 Control panel AlarmsUPS overloadElectronics faultBattery faultAmbient temp.> 40°CHold down to

Strany 4

Page 12 - 51033212EN/AC2. Installation2.1 Unpacking and checksElectronic moduleComet EXtreme 4.5 and 6 kVA23 24 2522battery module2527 RS 232 com

Strany 5

51033212EN/AC - Page 132. InstallationComet EXtreme 9 and 12 kVAElectronic module23242522Battery module2527 RS 232 communications cable. CD

Strany 6

Page 14 - 51033212EN/AC2.2 Installation of the rack version2. InstallationRack mounting diagram with railsThe rails and the necessary mounting hardwar

Strany 7

51033212EN/AC - Page 152. Installation2.3 Battery-module connectionsCheck that the battery circuit breaker is OFF.Check that the battery circ

Strany 8

Page 16 - 51033212EN/AC2. Installation2.4 Connection to the RS 232 communications port (optional)2.5 Installation of the communications-card optionSlo

Strany 9

51033212EN/AC - Page 172. InstallationThis type of connection must be carried out by qualified electrical personnel.Before carrying out any connectio

Strany 10 - Page 10 - 51033212EN/AC

Page 18 - 51033212EN/ACbypassbypass3. Operation3.1 ON-LINE operating modeThis is the normal operating mode for the UPS.Two possible cases:LED is

Strany 11 - 1. Presentation

51033212EN/AC - Page 19bypass3. Operation1114Prior to initial start-up, check the UPS voltage settings.The frequency of the output voltage (50 or 60

Strany 12 - Comet EXtreme 4.5 and 6 kVA

Page 2 - 51033212EN/ACIntroductionThank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.The Comet EXtreme range has

Strany 13 - Comet EXtreme 9 and 12 kVA

Page 20 - 51033212EN/ACbypassbypassbypass3. Operation3.4 Failure of AC input power and operation on battery powerAC input power is not available, the

Strany 14 - 2. Installation

51033212EN/AC - Page 213. Operation3.5 PersonalizationFunctionPersonalization parameters can be set and modified using the "UPS Driver" sof

Strany 15

Page 22 - 51033212EN/AC3. Operation"Battery" tabRated AC-power source voltage (see figure 1)Rated AC-power source frequencyTolerance for AC-

Strany 16

51033212EN/AC - Page 233. Operation221212Shutdown of connected equipment1. Press button (return to the OFF position).The connected equipment is

Strany 17

Page 24 - 51033212EN/AC4. Maintenance4.1 TroubleshootingIf one or more LEDs , , or flash, there is a operating anomaly or an ala

Strany 18 - 3. Operation

51033212EN/AC - Page 254. MaintenanceTroubleshooting requiring MGE after-sales supportIndicationLED flashes and the buzzerbeeps.LED flash

Strany 19

Page 26 - 51033212EN/ACbypass4. Maintenance4.2 Replacement of the electronic module1. Turn the manual bypass switch , located behind the UPS(see

Strany 20

51033212EN/AC - Page 271. Secure the connection module using the two screws .2. Reconnect the connection cable(s) to the battery module(s)

Strany 21 - Function

Page 28 - 51033212EN/AC5. EnvironmentThis product has been designed to respect the environment:It does not contain CFCs or HCFCs.It was manufactured i

Strany 22 - "By-pass" tab

51033212EN/AC - Page 296. Appendices6.1 GlossaryAuthorized voltage Upper and lower voltage thresholds within which the UPS can operaterange for trans

Strany 23 - Complete shutdown of the UPS

51033212EN/AC - Page 3ForewordUsing this documentInformation may be found primarily by consulting:◗ the contents,◗ the index.PictogramsImportant inst

Strany 24 - 4. Maintenance

Page 30 - 51033212EN/AC6. AppendicesOut of tolerance The AC input source is either absent or its voltage or frequency is outside theset limits.Percent

Strany 25

51033212EN/AC - Page 316. Appendices6.2 IndexAAC powerFailure ... 20Frequency tolerance ...

Strany 26

Page 32 - 51033212EN/AC

Strany 27

Page 4 - 51033212EN/ACContents1. Presentation1.1 Comet EXtreme range ...

Strany 28 - 5. Environment

51033212EN/AC - Page 5Contents3.4 Failure of AC input power and operation on battery power... 20Tran

Strany 29 - 6. Appendices

Page 6 - 51033212EN/AC1. Presentation1.1 Comet EXtreme range4.5 and 6 kVA tower models4.5 and 6 kVA rack modelsElectronic moduleBattery moduleDimensio

Strany 30

51033212EN/AC - Page 71. Presentation9 and 12 kVA tower models9 and 12 kVA rack modelsElectronic moduleBattery moduleDimensions in mm(H x W x D)443 x

Strany 31

Page 8 - 51033212EN/AC1. Presentation1.2 BackRS232 communications port.Battery circuit breaker.Communications-card option.EXB battery module connector

Strany 32 - Page 32 - 51033212EN/AC

51033212EN/AC - Page 91. Presentation1.3 OptionsTransformer for galvanic isolation or earthing arrangement changeImportant: to simplify installation,