www.mgeups.com Switched PDU THEUNINTERRUPTIBLEPOWERPROVIDERInstallation and user manual
3. Operations INTERFACES 12 Outlet Naming and Grouping 12 Usernames and Passwords 12 HTML INTERFACE 13 Logging In 13 Outlet Control 14 Individu
3. Operations Interfaces The Switched PDU has two interfaces: the HTML interface accessed via the HTTP enabled Ethernet connections and the command
3. Operations HTML Interface The HTML interface is constructed of three major components: the System Location bar, the User/Navigation bar and the
3. Operations Outlet Control The Outlet Control section offers access to the Individual and Group outlet control pages. From the Individual and Gro
3. Operations Environmental Monitoring The Environmental Monitoring section offers access to the Input Load page. This section is available to adm
3. Operations Network The Network configuration page is used for maintenance of the network interface. From this page an administrator may configur
3. Operations Setting the HTTP authentication method: The Switched PDU HTTP server supports two authentication methods for security and validation
3. Operations Outlets The Outlets configuration page is used for assignment and/or editing of outlet descriptive names and wakeup states. Editing th
3. Operations Changing a user’s access privilege level: The Switched PDU has four defined access privilege levels; Admin, User, On-Only and View-On
Instructions This symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literatu
3. Operations Setting the filename for upload: Enter the filename of the file to be uploaded in the Filename field, and press Apply. Testing the FTP
3. Operations Tools The Tools section contains access to rebooting the unit, uploading new firmware as well as resetting the unit to factory defaul
3. Operations Operations Command Summary Command Description On Turns one or more outlets on Off Turns one or more outlets off Reboot Reboot
3. Operations Administrative Command Summary (continued) Set FTP Filename Specifies the file to be uploaded via FTP Set FTP Filepath Specifies th
3. Operations Operations Commands Operations commands manage outlet states, provide information about the Switched PDU environment and control sessi
3. Operations Displaying outlet status The Status command displays the on/off status of one or more outlets. The command displays the status of on
3. Operations Displaying accessible outlets The List Outlets command displays accessible outlets for the current user. The display includes the abs
3. Operations Displaying accessible serial ports The List Ports command displays accessible serial ports for the current user. To display accessibl
3. Operations Displaying the status of the Environmental Monitor The Envmon command displays the status of the integrated Environmental Monitor. By
3. Operations Administration Commands Administration commands may only be issued by a user with administrative privileges, such as the predefined A
Contents GETTING STARTED 4 Quick Start Guide ...
3. Operations Changing a password The Set User Password command changes a user’s password. For security, when you type a password, the characters
3. Operations Granting and removing input status viewing privileges The Set User Envmon command grants or removes input status viewing privileges
3. Operations Deleting outlet access for a user The Delete OutletFromUser command removes a user’s access to one or all outlets. You cannot remove
3. Operations Displaying user outlet, group and serial port access The List User command displays all accessible outlets, groups and serial ports f
3. Operations Adding an outlet to a group The Add OutletToGroup command adds an outlet to a group. To add more than one outlet, but not all outlets
3. Operations Setting the outlet wakeup state The Set Outlet Wakeup command set the default wakeup state for that outlet. In the event of a system
3. Operations Serial Port Administration Creating a descriptive serial port name The Set Port Name command assigns a descriptive name to a serial p
3. Operations System Administration Creating a location description The Set Location command specifies text that appears in the HTML control screen
3. Operations Creating a descriptive tower name The Set Tower Name command assigns a descriptive name to a tower. This descriptive name is displaye
3. Operations Displaying the firmware version The Version command displays the firmware version. To display the firmware version: At the Switched P
1. Getting Started Quick Start Guide The following instructions will help you quickly install and configure your Switched PDU for use on your networ
3. Operations Displaying network configuration information The Show Network command displays TCP/IP, Telnet, SSH, Web, SSL and SNMP configuration in
3. Operations Setting the HTTP authentication method The Set HTTP Security command is used to set the method of authentication. The Switched PDU H
3. Operations Setting the FTP Password The FTP Password command sets the password as required by the FTP Host. To set the FTP password: At the Switc
3. Operations SNTP Administration Switched PDU supports the use of a network time service to provide a synchronized time reference. Setting the S
4. Advanced Operations SSL 45 Enabling and Setting up SSL Support 45 SSL Technical Specifications 45 SSH 46 Enabling and Setting up SSH Support
4. Advanced Operations SSL Secure Socket Layers (SSL) version 3 enables secure HTML sessions between a Switched PDU Remote Power Manager and a remo
4. Advanced Operations SSH Secure Shell (SSH) version 2 enables secure network terminal sessions between a Switched PDU Remote Power Manager and a r
4. Advanced Operations SNMP The Switched PDU family of products supports the Simple Network Management Protocol (SNMP). This allows network manage
4. Advanced Operations Setting trap destinations The Set SNMP Trapdest1 and Trapdest2 commands are used to set the IP addresses of SNMP management s
4. Advanced Operations Displaying SNMP configuration information The Show SNMP command displays all SNMP configuration information. • SNMP support
2. Installation Before installation, refer to the following lists to ensure that you have all the items shipped with the unit as well as all other
4. Advanced Operations Outlet Status traps Status Error Description On Outlet is on Off Outlet is off OnWait Outlet Status in transition Of
4. Advanced Operations Temp Trap The Temp trap is generated whenever the temperature on a temperature/humidity sensor is beyond preset thresholds.
4. Advanced Operations Configuring Traps SNMP Trap Command Summary Command Description Set Trap EM Status Enables or disables the Environmental Mo
4. Advanced Operations Enabling or Disabling a Load trap The Set Trap Infeed Load command is used to enable or disable an Infeed Load trap. To Enab
4. Advanced Operations Setting the Temperature sensor threshold limits The Set Trap THS Templow and Set Trap THS Temphigh commands are used to set t
4. Advanced Operations Displaying trap configuration information The Show Traps command displays information about all traps. To display trap infor
5. Appendices RESETTING TO FACTORY DEFAULTS 57 To reset to factory defaults from the HTML interface ...
5. Appendices Resetting to Factory Defaults You may reset the non-volatile RAM that stores all configurable options. This clears all administrator
5. Appendices Technical Specifications Models Europe/Asia Model Voltage Inlet Cordset (10’) Outlets RSNM-R8-E02 230V, 60Hz IEC 60320/C20 * 8
5. Appendices 301-0399-4 Rev A. - Page 59 Data Connections RS-232 port The Switched PDU is equipped standard with an RJ45 DTE RS-232c serial port.
2. Installation Equipment Overview A number is printed above each outlet. The outlets are labeled 1 through 16. These numbers may be used in comman
2. Installation Safety Precautions This section contains important safety and regulatory information that should be reviewed before installation an
2. Installation Mounting Horizontal/Rack e appropriate bracket mounting points within the rack. ts to these mounting points VerticalFigure 3. Mount
2. Installation Connecting Devices To avoid the possibility of noise due to arcing: 1. Keep the device’s on/off switch in the off position until a
Komentáře k této Příručce